Communicating Applications Spec - Get diagnostics results
Entry:
AX = CB13h
DL = 00h
Return:
AX = 0040h in progress
> 0 passed
< 0 failure code
Note: diagnostics return values are hardware dependent
Intel Connection CoProcessor failure codes:
bit 3: 9600 bps FAX modem module failed
bit 2: SDLC chip failed
bit 1: RAM failed
bit 0: ROM checksum failed